肌酐
胆红素
化学
溶血
色谱法
医学
内科学
生物化学
作者
Wen Shi,Jieru Huang,Dongdong Liu,Min He,Chuhong Zheng,Qian Xiao,Lin Li,Yile Huang,Lin Li,Jianhua Xu
标识
DOI:10.3760/cma.j.issn.1009-9158.2020.03.021
摘要
Objective
To investigate the interfering factors in the determination of creatinine(Cr) using the American Clinical Laboratory Standards Association (CLSI) EP7-A3 document.
Methods
According to the CLSI EP7-A3 document, fresh serum (no hemolysis, lipemia, and jaundice) was used on the day of the experiment and confirmed the interfering substances through the pairing difference experiment and the point-to-point analysis method was used in the dose effect experiment to clarify the difference of interfering substances.
Results
Triglyceride (16.94 mmol/L), dobutamine hydrochloride (4.01 μmol/L), ascorbic acid (298 μmol/L) did not interfere with the determination of Cr. Free bilirubin (684 μmol/L), conjugated bilirubin (684 μmol/L), calcium hydroxybenzene sulfonate (144 μmol/L) and hemoglobin (10 g/L) were used as the maximum concentrations of interferences for the dose effect test, the results showed that the above interferences had negative interference on the determination of Cr.
Conclusion
According to EP7-A3, it is valuable to evaluate the interference factors of creatinine determination.
Key words:
Interference experiment; Creatinine