The cutting tool is carrying an important role in machining process especially in milling
machine. During milling process, the cutting edge radius is the main contact on the material
workpiece.There are many factors that can influences the cutting tool such as spindle spindle
speed, cutting depth and cutting width. The cutting edge radius of tool will be easily to wear,
and the tool life will become shorter.
The title of this project is ‘Evaluation of cutting edge radius (CER) for tool wear in milling
DAC material’. Due to the high range of product to meet the diversified condition for
machining and material specification, the manufacturer is faced with a heavy product range to
produce. The product range can be reduced if different cutting edge radius (CER) in a mono
designed tool can be evaluate to cut a range of normal material hardness.
The objective in this study is to determine the optimum cutting edge of a mono designed tool
on tool performance in term of tool wear when machining on a DAC material. The cutting tool
used in this experiment was uncoated end mill carbide tool. By evaluating the cutting edge of
a mono designed tool on tool performance in term of tool life when machining on a DAC
material, the company will save a lot of inventory cost , easy to sell the product to customer
and reduce production range on designing different tool. This project helps to evaluate the
cutting edge radius of a cutting tool in term of tool wear to cater the different material
hardness.
There were 9 experiment done for 3 type of cutting edge radius in this project which are 20, 40
and 60 μm. Dry cutting process is performed for this experiment. An analysis was carried out by
using a Supereyes microscope and Design Expert after milling process.
The result taken from the microscope shows all the tools were wear off fast and the flank wear
value are higher than the recommended flank wear value. There are no suitable cutting edge
radius suitable in machining DAC. The reluctant cutting edge radius in this experiment that
could be accepted were CER 20 and CER40. Therefore, recommendation such as decreasing the
cutting depth from 6mm to less than or equal 0.5mm, add cutting fluid, increase number of flute
and apply coating on the cutting tool.