医学
植入
桥台
牙科
裂开
骨整合
随机对照试验
外科
工程类
土木工程
作者
Andy Temmerman,Simone Cortellini,Jeroen Van Dessel,Alexander De Greef,Reinhilde Jacobs,Rutger Dhondt,Wim Teughels,Marc Quirynen
摘要
Abstract Aim The aim of the study was to evaluate whether the use of a xenograft is not inferior to the use of xenograft and autogenous bone chips in treating dehiscences at implant placement. Materials and Methods After implant placement, leaving a dehiscence, control sites were treated using a composite graft (autogenous bone chips and xenograft) and at the test sites 100% xenograft was used. Both sites were covered with a resorbable collagen membrane. Dehiscences were measured clinically at implant placement and at re‐entry. CBCT was taken immediately after implant placement and after 4 months. Results In total, 28 GBR procedures were performed in 14 patients. On average, the change in vertical defect height was 2.07 mm (46.7%—test group) and 2.28 mm (50.9%—control group) ( p > .05). The horizontal defect width at the implant shoulder change on average 1.85 mm (40.5%—test group) and 1.75 mm (40.9%—control group) ( p > .05). On average, a loss in augmentation thickness of 0.45 mm (68.9%—test group) and 0.64 mm (55.5% control group) between implant placement and augmentation and abutment surgery was obtained at the implant shoulder. Conclusion Both treatment modalities seem to work to a certain extent. At implant shoulder level, the augmentation thickness seems to be disappeared after the healing phase. (NCT03946020).
科研通智能强力驱动
Strongly Powered by AbleSci AI