已入深夜,您辛苦了!由于当前在线用户较少,发布求助请尽量完整地填写文献信息,科研通机器人24小时在线,伴您度过漫漫科研夜!祝你早点完成任务,早点休息,好梦!

Influence of Corneal Visualization Scheimpflug Technology Tonometry on Intraocular Pressure

作者
Davide Borroni,Kunal A. Gadhvi,Rozaliya Hristova,Keri McLean,Carlos Rocha‐de‐Lossada,Vito Romano,Stephen B. Kaye
出处
期刊:Ophthalmology science [Elsevier BV]
卷期号:1 (1): 100003-100003 被引量:7
标识
DOI:10.1016/j.xops.2021.100003
摘要

PurposeTo investigate the effect of Corneal Visualization Scheimpflug Technology tonometry (CST) on intraocular pressure (IOP).DesignCohort study.ParticipantsPatients with and without primary open-angle glaucoma (POAG) were included.MethodsIntraocular pressure was measured using the Icare rebound tonometer (ICRT; Icare Finland Oy) and the biomechanically corrected IOP (bIOP) using the CST. Intraocular pressure was measured at baseline with ICRT, followed by a CST measurement in one eye with the fellow eye acting as a control. Icare measurements were repeated at 10 seconds and 1, 2, 4, 8, 15, 30, and 60 minutes in both eyes. The ratio of test eye IOP to fellow eye IOP was used to control for intrasubject variation.Main Outcome MeasuresIntraocular pressure change following Corneal Visualization Scheimflug Technology tonometry.ResultsForty participants (mean age, 54.09 ± 20.08 years) were included comprising 20 patients with POAG and 20 patients with no ocular abnormalities other than cataract. Mean central corneal thickness was similar in those without POAG (547.4 ± 55.05 μm) and with POAG (520.22 ± 37.59 μm; P = 0.14). No significant change was found in IOP measured with the ICRT in the fellow eye versus the 1-hour period in either the healthy (P = 0.87) or POAG (P = 0.92) group. Significant changes were found in IOP after CST measurement for both healthy (P < 0.01) and glaucomatous (P < 0.01) eyes. After the CST measurement, the IOP reduced continuously from a mean of 13.75 mmHg to 10.84 mmHg at 4 minutes for healthy eyes and from 13.28 mmHg to 11.11 mmHg at 8 minutes for glaucomatous eyes before approaching (83% for healthy eyes and 92% POAG eyes) the pre-CST measurement at 1 hour.ConclusionsCorneal Visualization Scheimpflug Technology tonometry causes a significant reduction in IOP in both glaucomatous and healthy eyes that lasts for at least 1 hour afterward. To investigate the effect of Corneal Visualization Scheimpflug Technology tonometry (CST) on intraocular pressure (IOP). Cohort study. Patients with and without primary open-angle glaucoma (POAG) were included. Intraocular pressure was measured using the Icare rebound tonometer (ICRT; Icare Finland Oy) and the biomechanically corrected IOP (bIOP) using the CST. Intraocular pressure was measured at baseline with ICRT, followed by a CST measurement in one eye with the fellow eye acting as a control. Icare measurements were repeated at 10 seconds and 1, 2, 4, 8, 15, 30, and 60 minutes in both eyes. The ratio of test eye IOP to fellow eye IOP was used to control for intrasubject variation. Intraocular pressure change following Corneal Visualization Scheimflug Technology tonometry. Forty participants (mean age, 54.09 ± 20.08 years) were included comprising 20 patients with POAG and 20 patients with no ocular abnormalities other than cataract. Mean central corneal thickness was similar in those without POAG (547.4 ± 55.05 μm) and with POAG (520.22 ± 37.59 μm; P = 0.14). No significant change was found in IOP measured with the ICRT in the fellow eye versus the 1-hour period in either the healthy (P = 0.87) or POAG (P = 0.92) group. Significant changes were found in IOP after CST measurement for both healthy (P < 0.01) and glaucomatous (P < 0.01) eyes. After the CST measurement, the IOP reduced continuously from a mean of 13.75 mmHg to 10.84 mmHg at 4 minutes for healthy eyes and from 13.28 mmHg to 11.11 mmHg at 8 minutes for glaucomatous eyes before approaching (83% for healthy eyes and 92% POAG eyes) the pre-CST measurement at 1 hour. Corneal Visualization Scheimpflug Technology tonometry causes a significant reduction in IOP in both glaucomatous and healthy eyes that lasts for at least 1 hour afterward.

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
加把劲骑士完成签到,获得积分10
1秒前
zyw完成签到,获得积分10
1秒前
1秒前
怕黑的又晴完成签到,获得积分10
3秒前
幕山白完成签到,获得积分10
3秒前
4秒前
6秒前
OK发布了新的文献求助10
8秒前
熙原发布了新的文献求助10
9秒前
9秒前
nieinei发布了新的文献求助10
10秒前
思源应助snowman采纳,获得10
10秒前
klein完成签到,获得积分10
13秒前
15秒前
15秒前
16秒前
16秒前
16秒前
酷波er应助淡定语采纳,获得10
16秒前
zengzeng完成签到,获得积分10
18秒前
18秒前
18秒前
19秒前
21秒前
21秒前
俏皮元珊发布了新的文献求助10
21秒前
21秒前
21秒前
21秒前
22秒前
充电宝应助LLZ采纳,获得30
23秒前
24秒前
24秒前
24秒前
25秒前
25秒前
25秒前
25秒前
25秒前
学术文献互助应助糟糕采纳,获得500
25秒前
高分求助中
Principles of Economics, 11th Edition 10000
University Physics with Modern Physics, 16th edition 10000
(应助此贴封号)【重要!!请各用户(尤其是新用户)详细阅读】【科研通的精品贴汇总】 10000
Arthritis and Related Conditions, An Issue of Orthopedic Clinics 1000
Development of a Bridge Weigh-In-Motion System: A technology to convert the bridge response to the passage of traffic into data on vehicle configurations, speeds, times of travel and weights 1000
ズームレンズの光学設計に関する研究 800
Fundamentals of Pharmaceutical and Biologics Regulations: A Global Perspective, Second Edition 700
热门求助领域 (近24小时)
化学 材料科学 医学 生物 纳米技术 工程类 有机化学 化学工程 生物化学 计算机科学 内科学 物理 复合材料 催化作用 细胞生物学 无机化学 光电子学 物理化学 电极 基因
热门帖子
关注 科研通微信公众号,转发送积分 7288854
求助须知:如何正确求助?哪些是违规求助? 8908372
关于积分的说明 18854738
捐赠科研通 6957340
什么是DOI,文献DOI怎么找? 3208959
关于科研通互助平台的介绍 2378678
邀请新用户注册赠送积分活动 2184731