小梁骨
曲面(拓扑)
材料科学
最小曲面
生物医学工程
计算机科学
数学
工程类
几何学
医学
病理
骨质疏松症
作者
Yutao Men,Shaocan Tang,Wei Chen,Fulong Liu,Chunqiu Zhang
出处
期刊:PubMed Central
[National Institutes of Health]
日期:2024-06-25
卷期号:41 (3): 584-594
标识
DOI:10.7507/1001-5515.202310005
摘要
Triply periodic minimal surface (TPMS) is widely used because it can be used to control the shape of porous scaffolds precisely by formula. In this paper, an I-wrapped package (I-WP) type porous scaffolds were constructed. The finite element method was used to study the relationship between the wall thickness and period, the morphology and mechanical properties of the scaffolds, as well as to study the compression and fluid properties. It was found that the porosity of I-WP type scaffolds with different wall thicknesses (0.1 ~ 0.2 mm) and periods (I-WP 1 ~ I-WP 5) ranged from 68.01% ~ 96.48%, and the equivalent elastic modulus ranged from 0.655 ~ 18.602 GPa; the stress distribution of the scaffolds tended to be uniform with the increase of periods and wall thicknesses; the equivalent elastic modulus of the I-WP type scaffolds was basically unchanged after the topology optimization, and the permeability was improved by 52.3%. In conclusion, for the I-WP type scaffolds, the period parameter can be adjusted first, then the wall thickness parameter can be controlled. Topology optimization can be combined to meet the design requirements. The I-WP scaffolds constructed in this paper have good mechanical properties and meet the requirements of repairing human bone tissue, which may provide a new choice for the design of artificial bone trabecular scaffolds.
科研通智能强力驱动
Strongly Powered by AbleSci AI