Comparison of Switching Strategies for an Ultrasonic Cleaner
作者
Chankit Buasri,Anuwat Jangwanitlert
出处
期刊:日期:2008-05-01卷期号:: 1005-1008被引量:20
标识
DOI:10.1109/ecticon.2008.4600602
摘要
This paper presents the comparison of Control Signal Patterns in ultrasonic cleaner by using the microcontroller for generating Pulse-Width Modulation (PWM), Phase-Shift PWM control (PS-PWM) and Pulse Density Modulation (PDM) patterns. These control patterns are fed in the full-bridge inverter to drive the ultrasonic transducers. The resonant frequency of 30 kHz is tested in order to find the efficiency of ultrasonic cleaner which one should be the best. Ultrasonic transducer can generate ultrasonic wave to transfer electrical energy to mechanical energy. Cavitation and implosion are occurred in liquid when ultrasonic wave travels through liquid medium in the process of cleaning.