In this paper, we considered multiple faults detection on a coaxial cable through Time-Frequency Domain Reflectometry (TFDR). It is well known that TFDR has high resolution accuracy for detecting and estimating the fault detection on a coaxial cable. This approach was based on time-frequency signal analysis and utilized a chirp signal multiplied by a Gaussian time envelope. The Gaussian envelope provided time localization, while the chirp allowed one to excite the system interest. We carried out experiments with 10C-FBT coaxial cable having either one or two faults. The result shows TFDR can be extended to detect multiple faults with high accuracy on a coaxial cable.