BACKGROUND: Dentin hypersensitivity is a common painful clinical condition affecting
72.5-98% of periodontal patients. It has been observed in approximately half of the
patients following scaling and root planing. The current opinion based on Brannstrom
hydrodynamic theory suggests dentin tubule occlusion as a logical treatment for dentin
hypersensitivity.
AIM: To compare the dentinal tubule occluding ability of Pro-Argin based dentifrice and
Carbon Dioxide Laser in the treatment of dentinal hypersensitivity.
MATERIALS AND METHODS: Thirty single rooted human teeth extracted due to advanced
periodontal disease were used in this study. The teeth were scaled and root planed. Thirty
dentin discs were prepared and randomly divided into three groups. In group I, the
specimens were stored in Distilled Water (DW); in group II, the specimens were brushed
with Pro-Argin based dentifrice (PA); in group III, the specimens were irradiated with
Carbon Dioxide Laser (CDL). All the specimens were fixed and observed under scanning
electron microscope.
RESULTS: The Carbon Dioxide Laser group showed the maximum number of completely
occluded tubules followed by Pro-Argin and Distilled Water group. Pro-Argin group
showed more number of partially occluded tubules than the other two groups. The
reduction in tubule diameter was also highest in carbon dioxide laser group.
CONCLUSION: The Carbon dioxide laser proved to be most efficient in the occlusion of
patent dentinal tubules. The partial tubule occlusion achieved by Pro-Argin is also valuable
as decrease in the tubule diameter causes decrease in the pain due to dentinal
hypersensitivity.