生物炭
蔗渣
电化学
零电荷点
吸附
电极
化学
循环伏安法
锰
阳极溶出伏安法
无机化学
镉
电化学气体传感器
化学工程
材料科学
安培法
微分脉冲伏安法
碳纤维
碳糊电极
伏安法
吸附溶出伏安法
热解
线性扫描伏安法
参比电极
核化学
支撑电解质
生物量(生态学)
铜
工作电极
电解质
氧化还原
棕榈仁
比表面积
剥离(纤维)
软锰矿
扫描电子显微镜
分析化学(期刊)
电位滴定法
作者
Manascha Seif Eddine Smit,Rafael Matias Silva,Thamiris Ferreira Souza,Mylene Lourdes Barbosa,Guilherme Max Dias Ferreira,Tiago Almeida Silva
标识
DOI:10.1016/j.biortech.2026.135262
摘要
Cadmium (Cd) is a toxic metal widely used in batteries, pigments, and coatings, and its presence in natural environments poses a serious risk to human health. This study aimed to develop an electrochemical sensor based on a carbon paste electrode modified with manganese oxide-functionalized sugarcane bagasse biochar for Cd 2+ determination using differential pulse adsorptive anodic stripping voltammetry (DPAdASV), providing a sustainable strategy that combines biomass valorization with enhanced electrochemical performance. Manganese precursors with different oxidation states (MnCl 2 or KMnO 4 ) were employed to produce biochars with distinct MnOx phase compositions, enabling the investigation of the relationship between the nature of these phases and the electroanalytical performance of the resulting materials. Biochars produced via manganese pretreatment of sugarcane bagasse with different precursor salts were characterized by Fourier-transform infrared, Raman spectroscopy, determination of the point of zero charge (pH PZC ), quantification of acidic and basic surface functions, and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy. Cd 2+ ions were adsorbed onto the electrode surface and subsequently determined electrochemically. The electrode containing biochar obtained from KMnO 4 exhibited superior performance, evidenced by a more intense analytical signal. Adsorption assays using Cd 2+ on the biochars confirmed that the nature of the oxides formed governs the electrochemical activity of the electrode. Experimental parameters such as biochar content (30% w w −1 ), pH (4.5), reduction potential (–1.0 V), pre-accumulation time (10 min), and reduction time (60 s) were optimized. Under optimized conditions, the sensor displayed a linear response in the concentration range of 0.498–4.76 µmol L −1 and a sensitivity of 1.178 µA L µmol −1 . The limits of detection (LOD) and quantification (LOQ) were 0.02 µmol L −1 and 0.06 µmol L −1 , respectively. Recovery tests for river and tap water samples showed values above 80%, confirming the sensor’s applicability for environmental monitoring. Interference studies demonstrated satisfactory selectivity toward Cd 2+ in the presence of common inorganic ions and organic species found in environmental waters.
科研通智能强力驱动
Strongly Powered by AbleSci AI