逆流交换
数据清理
传质
化学
塔楼
分析化学(期刊)
体积流量
色谱法
压力降
下降(电信)
机械
热力学
废物管理
工程类
土木工程
物理
电信
计算机科学
作者
Aaron M. Turpin,Annabelle Couvert,A. Laplanche,Anne Paillier
摘要
Abstract The aim of this study was to characterize mass transfer and deodorization efficiency in a countercurrent spray tower for low superficial gas velocities. The influence of operating parameters ( U G = 0.005 to 0.025 m s −1 , U L = 6.1 × 10 −5 to 2.4 × 10 −4 m s −1 ) on the liquid retention ( ε L ), the drop diameter ( d g ), the interfacial area ( a ) and the overall liquid and gas phase mass transfer coefficients ( K L a , K G a ) were estimated. The spray efficiency of some malodorous compounds was also estimated. A negative influence of the superficial gas velocity was demonstrated, during the spraying of water or chemical neutralizing scrubbing solutions. There was also an increase with the liquid flow rate. Abatements obtained were very good with respect to ammonia (>90%), and acceptable for the other compounds.
科研通智能强力驱动