医学
灌注
活检
磁共振成像
动态增强MRI
放射科
接收机工作特性
灌注扫描
核医学
病变
病理
内科学
作者
Youxin Guan,Kyung K. Peck,John K. Lyo,Jamie Tisnado,Eric Lis,Julio Arévalo‐Pérez,Yoshiya Yamada,Meera Hameed,Sasan Karimi,Andrei I. Holodny
出处
期刊:Radiology
[Radiological Society of North America]
日期:2020-09-01
卷期号:297 (2): 382-389
被引量:22
标识
DOI:10.1148/radiol.2020190553
摘要
Background Dynamic contrast agent-enhanced (DCE) perfusion MRI may help differentiate between nonneoplastic and malignant lesions in the spine. Purpose To investigate the correlation between fractional plasma volume (Vp), a parameter derived from DCE perfusion MRI, and histopathologic diagnosis for spinal lesions. Materials and Methods In this retrospective study, patients who underwent DCE perfusion MRI and lesion biopsy between May 2015 and May 2018 were included. Inclusion criteria were short time interval (<30 days) between DCE perfusion MRI and biopsy, DCE perfusion MRI performed before biopsy, and DCE perfusion MRI performed at the same spine level as biopsy. Exclusion criteria were prior radiation treatment on vertebrae of interest, poor DCE perfusion MRI quality, nondiagnostic biopsy, and extensive spinal metastasis or prior kyphoplasty. One hundred thirty-four lesions were separated into a nonneoplastic group (n = 51) and a malignant group (n = 83) on the basis of histopathologic analysis. Two investigators manually defined regions of interest in the vertebrae. DCE perfusion MRI parameter Vp was calculated by using the Tofts pharmacokinetic two-compartment model. Vp was quantified, normalized to adjacent normal vertebrae, and compared between the two groups. A Mann-Whitney U test and receiver operating characteristic analysis was performed to verify the difference in Vp between the nonneoplastic and malignant groups. Reproducibility was assessed by calculating the Cohen κ coefficient. Results One hundred patients (mean age, 65 years ± 11 [standard deviation]; 52 men) were evaluated. Vp was lower in nonneoplastic lesions versus malignant lesions (1.6 ± 1.3 vs 4.2 ± 3.0, respectively; P < .001). The sensitivity of Vp was 93% (77 of 83; 95% confidence interval [CI]: 85%, 97%), specificity was 78% (40 of 51; 95% CI: 65%, 89%), and area under the receiver operating characteristic curve was 0.88 (95% CI: 0.82, 0.95). Cohen κ coefficient suggested substantial agreement in both intra- (κ = 0.72) and interreader (κ = 0.70) reproducibility. Conclusion This study indicated that dynamic contrast agent-enhanced perfusion MRI parameter, fractional plasma volume, was able to differentiate between nonneoplastic spinal lesions and malignant lesions. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Haller in this issue.
科研通智能强力驱动
Strongly Powered by AbleSci AI