For MEMS gyroscopes,biases characteristics always vary with temperature fluctuations. Through establishing error model between the temperature and the MEMS gyroscope biases,the biases outputs of the MEMS gyroscope are studied within a temperature range of-20 ℃ ~ 60 ℃. Via using the error model after removing outliers,results show that MEMS gyroscope biases caused by temperature have changed from approximately 100 ° / h to approximately 10 ° / h after compensations. Also biases in the whole temperature range have been improved to some extent,which would lay a foundation for improving the navigation accuracy.