医学
内镜逆行胰胆管造影术
倾向得分匹配
透视
不利影响
观察研究
外科
胆总管
胰腺炎
放射科
辐射暴露
胆管
内窥镜检查
回顾性队列研究
普通外科
胆总管结石
并发症
随机对照试验
作者
Dehua Tang,Ruyan Yan,Lin Zhou,Yonghua Shen,C Yang,Peng Yan,Ningjing Gao,Bin Zhang,S Shen,Ye Fu,Yuxuan Cheng,Hao Zhu,Muhan Ni,Xiang Zhang,Ruhua Zheng,Bingyi Liu,Tianyu Xie,Lei Wang
出处
期刊:Endoscopy
[Thieme Medical Publishers (Germany)]
日期:2026-06-12
卷期号:58 (10): 1123-1131
摘要
Background: Robotic assistance may mitigate occupational hazards associated with endoscopic retrograde cholangiopancreatography (ERCP). We evaluated the safety, feasibility, and learning curve of a new ERCP robotic system. Methods: In this observational study, 26 patients with common bile duct stones underwent robotic-assisted ERCP; 6 underwent biliary cannulation only and 20 underwent stone extraction. For the 20 cases with stone extraction, comparisons were performed using 1:1 propensity score matching (PSM) with conventional ERCP performed by the same operator. The safety outcome was adverse events. Feasibility outcomes included technical success, procedural times, operator radiation exposure, and learning-curve characteristics. Results: After PSM, adverse event rates were similar between groups. Post-ERCP pancreatitis occurred in 15.0% (3/20, robotic) and 10.0% (2/20, conventional) (P >0.99), with no bleeding, perforation, or procedure-related mortality. Biliary cannulation and stone extraction success rates were 100% (20/20) in both groups. Robotic-assisted ERCP had a longer procedure time (36.6 vs. 17.0 minutes; P < 0.001), but similar cannulation and fluoroscopy times. In robotic-assisted procedures, radiation exposure was markedly lower in the control room than in the operation room (0.10 vs. 1.26 μSv; P < 0.001). Learning-curve analysis suggested performance stabilization after 10-12 cases. Conclusions: Robotic-assisted ERCP appeared safe and feasible, with high technical success and substantially reduced operator radiation exposure.
科研通智能强力驱动
Strongly Powered by AbleSci AI