母线
电流传感器
电气工程
电子工程
工程类
电磁干扰
电流(流体)
磁铁
功率(物理)
作者
X. P. Xu,S. Wang,T. Z. Liu,Min Zhu,J. G. Wang
出处
期刊:IEEE Transactions on Instrumentation and Measurement
[Institute of Electrical and Electronics Engineers]
日期:2021-01-01
卷期号:70: 1-9
被引量:7
标识
DOI:10.1109/tim.2021.3089775
摘要
Busbar current sensor without magnetic core is used more and more in compact power electronic equipment due to its small size and lightweight. The differential measurement technique is generally adopted to resist external magnetic interference. The sensitivity of busbar current sensors varies with the frequency of the sensed current due to the skin effect in the busbar. Traditional coreless busbar current sensors can accurately measure dc current, but the measurement error increases when sensing high-frequency ac current. A coreless sensor configuration based on four tunneling magnetoresistance (TMR) chips is proposed in this article with high measurement accuracy for both dc and high-frequency ac currents while eliminating the effect of magnetic stray field. An optimization method is introduced for the layout of the TMR chips around the busbar in order to obtain a current error below 1.5% up to 1 kHz. The effectiveness of the proposed sensor configuration and layout optimization method are verified by finite element simulation and prototype tests.
科研通智能强力驱动
Strongly Powered by AbleSci AI