医学
不利影响
外科
重症监护医学
梅德林
数据库
内科学
放射科
患者数据
并发症
作者
Azadeh Shafieesabet,Amanda N. Cooper,Flynn McGuire,Reza Ehsanian,Allison Glinka Pryzbysz,Zachary L. McCormick,Alexandra E.C. Fogarty
标识
DOI:10.1016/j.inpm.2026.100801
摘要
Background: Basivertebral nerve ablation (BVNA) is a minimally invasive intraosseous radiofrequency procedure for vertebrogenic chronic low back pain (CLBP). Although randomized controlled trials have established its efficacy, real-world safety data remain limited. Purpose: Post-market adverse event (AE) characterization associated with BVNA using the U.S. Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) database. Study design: Retrospective analysis of a national medical device adverse event database. Methods: The MAUDE database was queried for all reports involving FDA-cleared BVNA systems from inception to 2025. Reports were manually reviewed, deduplicated, and coded for AE type, severity, timing, and outcome. Frequencies were summarized with descriptive statistics. Results: A total of 96 unique medical device reports were analyzed. Vertebral compression fracture was the most frequently reported AE, occurring in 21.9% (21/96) of reports. Among the 21 VCF-containing reports, timing was documented in 12 (57.1%): 6 occurred within 30 days post-procedure (range: 4-21 days) and 6 occurred beyond 30 days (range: 33-294 days). Timing was not reported in the remaining 9 reports. An additional 2 reports described posterior element fractures and are reported separately (2.1%, 2/96). Other common AEs included increased low back pain (10.4%), superficial bleeding (2.1%), and emergency department visits (7.3%). Severe AEs were infrequent, including hospitalization (9.4%), retroperitoneal hematoma (7.3%), and death (2.1%). Both deaths were associated with anesthesia-related events rather than the BVNA device or procedure. No cases of infection, spinal/epidural hematoma, or major neurologic injury were identified. Most reports were manufacturer-submitted, with few voluntary reports or device returns. Conclusions: This MAUDE-based review complements clinical trial data by characterizing the distribution of post-market adverse event reports associated with BVNA. Vertebral fracture was the most frequently reported event, with variable timing ranging from the day of the procedure to nearly 300 days post-BVNA; no consistent temporal pattern could be established. These findings do not permit conclusions about incidence or causality but identify vertebral fracture and pain as the most represented post-market signals, and highlight the need for prospective registries with standardized follow-up, pre-procedural bone health documentation, and detailed AE capture to more precisely define the long-term safety profile of BVNA.
科研通智能强力驱动
Strongly Powered by AbleSci AI