Abstract For patients with persistent atrial fibrillation(PAF), whether linear ablation should be performed remains controversial, and the efficacy and safety for ablation index༈AI༉guided high energy linear ablation of mitral isthmus (MI) and left atrial (LA) posterior wall is still unclear. The aims of the this study were to assess the feasibility and clinical success rate of pulmonary veins isolation (PVI) combined with AI-guided high‐power linear ablation of LA roof and posterior inferior༈LA posterior wall isolation༉and MI for PAF patients. 200 consecutive PAF patients were enrolled. PVI combined with linear ablation of left atrial posterior wall isolation༈LAPWI༉ and MI were performed in all patients using AI-guided high-power pattern (ablation power was set to 45 W, targeting AI 400–500). The confirmation of the MI linear conduction block and LAPWI were performed after ablation. The procedure-related complication rate was 2.0%. During an average follow-up period of 24 months, freedom from atrial fibrillation or atrial tachycardia was achieved in 87.5% of the patients. Our ablation strategy of linear ablation was feasible and safe for PAF patients.