镉
检出限
化学
洗脱
盐酸
水溶液
原子吸收光谱法
固相萃取
吸附
分析化学(期刊)
色谱法
吸附剂
萃取(化学)
富集因子
无机化学
有机化学
物理化学
物理
量子力学
作者
Reza Hafezi Moghaddam,Ali Mohammad Haji Shabani,Shayessteh Dadfarnia,Neda Baghban
标识
DOI:10.5935/0103-5053.20140179
摘要
Cadmium was quantitatively adsorbed from aqueous sample onto a microcolumn packed with cadion immobilized on sodium dodecyl sulfate-coated TiO2 nanoparticles. The retained cadmium was eluted with 2.5 mol L-1 hydrochloric acid solution and measured by cold vapor atomic absorption spectrometry (CVAAS). The influences of different variables such as pH, sample and eluent flow rates, amount of the sorbent and volume of the sample on the recovery of cadmium were investigated. Under the optimum conditions, a sample volume of 200 mL resulted in a preconcentration factor of 100. The precision (RSD%, n = 8) at the 0.05 µg L-1 level of cadmium was 3.6% and the limit of detection based on three times the standard deviation of blank solution (3Sb) was 1.3 ng L-1. The method was successfully applied to the determination of cadmium in rice, fish, milk, and water samples.
科研通智能强力驱动
Strongly Powered by AbleSci AI