Xiaobing Zou,Huantong Shi,H. Xie,Xinxin Wang,Guixin Zhang
摘要
A small-scale fast risetime gas switch attached to a 50 Ω pulse forming line is tested. It includes a fast moving electrode and a fixed electrode. For the applied direct voltages, such as 2.8 kV, 2.0 kV, and 1.0 kV, the risetimes of this switch are tested to be ∼3.8 ns, ∼2.3 ns, and ∼1.1 ns, respectively, while the risetimes of a switch with two fixed electrodes are about ∼10.1 ns, ∼9.0 ns, and ∼3.6 ns. The results of high-speed photography and laser interferometry reveal that the moving electrode will obviously shorten discharge spark length but almost will not change the inter-electrodes gas pressure. The reason of shortening spark length is the existence of the discharge time delay of gas switch. After moving to the static breakdown spacing, the fast moving electrode will move on for an additional distance within the discharge time delay, which makes gas switch achieve overvoltage breakdown under high direct voltages and therefore leads to shorter spark length and faster switch risetime.