Elmar Spuentrup,Karl Rühl,René M. Botnar,Andrea J. Wiethoff,Alexandra Buhl,Vincent Jacques,Matthew T. Greenfield,Gabriele A. Krombach,Rolf W. Günther,Márk Vangel,Peter Caravan
出处
期刊:Circulation
[Lippincott Williams & Wilkins]
日期:2009-03-24
卷期号:119 (13): 1768-1775
被引量:60
标识
DOI:10.1161/circulationaha.108.826388
摘要
BACKGROUND: Cardiac magnetic resonance (MR) perfusion imaging during the first pass after intravenous administration of extracellular contrast agents is hampered by the spatial and temporal resolution achievable and by the artifacts seen in ultrafast MR imaging. Furthermore, time-consuming quantitative data analysis is often added. The use of molecular MR imaging with a target-specific contrast agent with perfusion-dependent binding to myocardium may enable prolonged visualization of perfusion defects and thus may help to overcome limitations of currently used first-pass extracellular MR imaging. EP-3600 is a new gadolinium-containing molecular contrast agent that binds reversibly to myocardial collagen. METHODS AND RESULTS: A significant but nonocclusive coronary artery stenosis was modeled in 7 domestic swine with an undersized MR-compatible balloon positioned in the left anterior descending artery as verified by x-ray angiography. Two animals died before contrast injection as a result of arrhythmias. In 5 swine, high-spatial-resolution gradient echo imaging (approximately 1 x 1 mm(2) in-plane resolution) was performed before and 5, 20, 40, and 60 minutes after intravenous administration of 12.3 micromol/kg EP-3600. Contrast was administered during stress induced by an infusion of 250 mumol x kg(-1) x min(-1) adenosine. Yb-DTPA was administered simultaneously for comparison of myocardium-to-plasma ratios. Images were assessed subjectively by 2 investigators, and signal-to-noise and contrast-to-noise ratios over time were calculated. Normal myocardium showed a significant signal-to-noise ratio increase during the entire examination time. In all animals (n=5), the perfusion defect in the left anterior descending artery territory could be visualized with a high contrast-to-noise ratio for at least 20 minutes after contrast injection. A significantly higher myocardium-to-plasma ratio was found for EP-3600 compared with the control agent Yb-DTPA (0.85+/-0.26 versus 0.22+/-0.08, respectively; P<0.01). CONCLUSIONS: EP-3600 is a new molecular MR imaging contrast agent that binds to the myocardium and enables prolonged, high-contrast, high-spatial-resolution visualization of myocardial perfusion defects.
科研通智能强力驱动
Strongly Powered by AbleSci AI