作者
Dale A. Raines,A. J. Yusuf,Monzer Jabak,WaelS. Ahmed,Zeynel A. Karcioglu,A el-Yazigi
标识
DOI:10.1097/00007691-199812000-00018
摘要
This article describes a high-performance liquid chromatographic (HPLC) method for the measurement of azithromycin (AZI) and two of its metabolites, 9a-N-desmethylazithromycin (ADES) and N-desmethylazithromycin (NDES), in human tears and plasma. The drug, metabolites, and internal standard (n-propylazithromycin [IS]) were detected electrochemically after injection of the extracted sample into the HPLC system. The peak height ratio (AZI, ADES, or NDES to IS) varied linearly, with concentrations in the ranges of 0.1 mg/L to 2.0 mg/L (tears) and 0.01 mg/L to 2.0 mg/L (plasma) of AZI, ADES, and NDES; the correlation coefficient (r) was more than 0.994 mg/L for all of the compounds (n = 6). The analysis of tear samples collected at different intervals within 12 hours to 144 hours after a dose of 20 mg/kg of AZI from a trachoma patient yielded concentrations ranging from 1.52 mg/L to 0.34 mg/L for AZI, 0.79 mg/L to 0.27 mg/L for ADES, and 1.99 mg/L to less than 0.20 mg/L for NDES. The concentration of AZI in plasma ranged from 0.15 mg/L to 0.01 mg/L, whereas ADES and NDES were undetectable.