Current practice for the handling of pure tritium gas involves the use of inert atmosphere glove boxes. The purity of the inert gas is maintained by recirculation through a purification system. Due to the high toxicity of tritium in the form of water it is desirable to avoid oxidation of the elemental tritium and to remove tritium by forming stable metal tritides. This paper describes the use of SAES ST707 Alloy for the removal of hydrogen from a glove box atmosphere and briefly relates largely unsuccessful attempts at hydrogen removal using a variety of metals and alloys. The details of a proposed purification system for the control of chronic tritium releases and for the collection and recovery of a large tritium release are presented.