作者
Álvaro García-Padilla,Juan S. Herranz,Lorenz Gubler,Pierre Boillat
摘要
The sluggish O 2 -reduction kinetics and mass transport limitations at high current densities are the main performance drawbacks and cost drivers for polymer electrolyte fuel cells (PEFCs). As such, improving the bipolar plate (BPP) design and decreasing the complexity of balance of plant components would reduce these devices’ cost. In this context, BPPs with interdigitated flow fields (IFFs) are known to enhance O 2 -convection from the dead-ended inlet channels to the outlet channels, thus promoting a better gas distribution 1 that can allow a reduction of the gas stoichiometry and ease the concomitant requirements in fluid management and handling components. However, IFFs reportedly suffer from an accumulation of water in the dead-ended channels at high current densities that hinders their operational stability 2 – an issue that can be mitigated using gas diffusion layers (GDLs) with high water discharge capability, such as patterned wettability GDLs 3,4 . With this motivation, this study investigates the influence of the flow field and GDL design on the electrochemical performance and operating stability of 12 cm 2 single fuel cells at different current densities and cathode stoichiometries (down to 1.2). The tests were performed feeding hydrogen at 75% relative humidity (RH) to the anode and air at 100% RH to the cathode, at an absolute pressure of 2 bar and 70 °C. A straight parallel flow field (PFF) with a land-to-channel ratio of 1 and a commercial hydrophobic GDL with a microporous layer were selected as the benchmark components. Firstly, the effect of the GDL’s pattern coverage was analyzed using full-, half-, and quarter-coverage designs. All the IFF combinations led to a higher cell potential than the benchmark case (see Figure 1a ) thanks to the forced oxygen convection induced by the dead-ended channels. However, Figure 1b shows that the corrected pressure drop in the cathode was significantly higher for the IFF designs, especially for the hydrophobic GDL prepared in-house (H23IH) in which water might have been accumulated in the inlet dead-ended channels. The patterned GDLs seem to successfully reduce pressure drop by efficiently transporting the water to the outlet channels while increasing the oxygen availability in the active sites. Additionally, the half-coverage patterned GDL exhibited the best performance. Further analyses include the effect of the pattern spacing between the hydrophilic lines (i.e., reduced or increased by 50% compared to the baseline patterned GDL) on the cell performance, as well as the increase of the land-to-channel ratio to 2.3 and 4.0. Lastly, the sharp channel’s edge architecture was compared with a slanted edge to evaluate how this affects the oxygen convection behavior. To this end, mass transport losses were studied using pulse gas analysis for the best designs of IFF and p-GDL, and compared with the benchmark. References T. Van Nguyen, J. Electrochem. Soc. , 143 , L103 (1996). T. Van Nguyen and M. W. Knobbe, J. Power Sources , 114 , 70–79 (2003). A. Forner-Cuenca, J. Biesdorf, L. Gubler, P. M. Kristiansen, T. J. Schmidt, and P. Boillat, Adv. Mater. , 27 , 6317–6322 (2015). V. Manzi-Orezzoli, M. Siegwart, M. Cochet, T. J. Schmidt, and P. Boillat, J. Electrochem. Soc. , 167 , 054503 (2019). Figure 1