右旋糖酐
生物传感器
化学
胺气处理
共价键
共轭体系
分子
抗体
色谱法
生物化学
有机化学
聚合物
生物
免疫学
作者
Steve W. Howell,Mike Kenmore,Mark A. Kirkland,R. Andy Badley
标识
DOI:10.1002/(sici)1099-1352(199812)11:1/6<200::aid-jmr423>3.0.co;2-7
摘要
There are numerous chemical methods published that enable protein coupling to carboxymethyl (CM) dextran. Here we have taken traditional amine coupling using N-hydroxysuccinimide (NHS) and N'-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) and coupled an antibody fragment (scFv) to CM dextran at a very high density. Using an upgraded BIAlite from Biacore AB, more than 7000 RU of scFv was coupled to a CM dextran biosensor chip. In addition, scanning electron microscopy was performed on CM dextran biosensor chips following amine coupling of 30 nm gold anti-IgG particles. This showed that amine coupling was uniform across the biosensor chip surface. Calculations show that 7620 RU of an scFv coupled to such a surface results in a mean distance between binding sites of 8.8 nm. This equates to a packing volume of approximately 20% of the available space occupied by the antibody fragment. Comparisons made with densities of covalently coupled IgG show that a greater number of antibody fragment molecules can be coupled per unit area. This is most likely due to the smaller size of an antibody fragment (scFv), which has a volume of less than 20% of an IgG molecule. The significance of these findings is discussed.
科研通智能强力驱动
Strongly Powered by AbleSci AI