In the context of achieving carbon neutrality, the peak shaving techniques applied to coal-fired units provide the ability to operate flexibly across a wide load range, which leads to notable changes in the flow field and combustion characteristics, and significantly affects the NOx emissions. Meanwhile, the air-fuel ratio is a key variable that is often adjusted to achieve the optimal operating condition. Nevertheless, little attention has been given to the coupled dynamics of the flow field and combustion characteristics of a wall-fired boiler during load reduction, with effective adjustment strategies for optimal low-load performance remaining particularly understudied. In this paper, numerical simulation is employed to investigate the flow, temperature, component, and NOx formation characteristics of a 350 MW wall-fired boiler under base load (300 MW) and low load (150 MW), with varying layered air-fuel ratios of burners. The simulations indicate that increasing the bottom-layer air-fuel ratio from 0.95 to 1.58 leads to the formation of a low-temperature region in the primary combustion zone under both base load and low load. In contrast, decreasing of the bottom-layer air-fuel ratio from 0.95 to 0.68 results in a substantial amount of pulverized coal remaining unburned in the ash hopper, indicating incomplete combustion. The final NOx emission first increases and then decreases as the bottom-layer air-fuel ratio increases from 0.68 to 1.58, according to the production of thermal NOx. As the load decreases from 300 MW to 150 MW, the area-averaged temperature and NOx concentration reduce, and they have a similar trend with respect to the layered air-fuel ratio. The high-temperature zones near the upper walls of the boiler, which result from the combustion of unburned pulverized coal from the middle- and top-layer burners and usually cause significant thermal corrosion, disappear under low load. For low-load operation, case 3 with a balanced air-fuel distribution is preferable because it achieves high combustion efficiency without notable rise in NOx emissions. Under base conditions, the layered air-fuel ratio should be carefully regulated to achieve a balance between enhanced combustion intensity (case 9) and reduced NOx formation (case 8).