Abstract Isothermal vapor‐liquid equilibrium data for propane‐isobutane, a system of industrial importance, have been obtained in two pieces of apparatus at temperatures from 20° to 250°F. Over this temperature range, propane‐isobutane form ideal solutions. The paper discusses the sampling errors which occur in volatile systems.