Molded, Gamma-radiated, Argon-processed Polyethylene Components of Rotating Hinge Knee Megaprostheses Have a Lower Failure Hazard and Revision Rates Than Air-sterilized, Machined, Ram-extruded Bar Stock Components

医学 聚乙烯 外科 骨科手术 口腔正畸科 复合材料 材料科学
作者
Ana C. Belzarena,Mohammad A. Elalfy,Mohamed A. Yakoub,John H. Healey
出处
期刊:Clinical Orthopaedics and Related Research [Lippincott Williams & Wilkins]
卷期号:479 (1): 95-101 被引量:3
标识
DOI:10.1097/corr.0000000000001439
摘要

Abstract Background Megaprostheses are commonly used for reconstruction after distal femoral resection in orthopaedic oncology. The polyethylene bearings in these reconstructions experience wear and wear-related complications that may result in revision surgery. Improved manufacturing and processing of polyethylene has increased the durability of components commonly used for routine arthroplasty. Alterations in the manufacture of polyethylene is expected to reduce the revision risk of oncologic megaprostheses, resulting in fewer revision procedures, but this has not been proven. Questions/purposes Is there a difference in the hazard of polyethylene wear or breakage leading to prosthetic revision between differences in polyethylene manufacture and processing based on a competing risk analysis? Methods This was a single-center, observational, retrospective comparative study of 224 patients who had distal femur megaprostheses with identical rotating hinge articulations and knee kinematics after oncologic surgery from 1993 to 2015. No differences in surgical indications, joint articular components and kinematics, age, sex, diagnosis, BMI, use of chemotherapy, or tumor stage were seen with the patient numbers available. Prosthetic survivorship free from prosthetic revision surgery because of polyethylene wear-related revisions, defined as breakage, increased excursion on varus-valgus stress, or new locking or giving way was compared between two groups of patients: group 1 polyethylene (P1) (66 patients) who had air-sterilized machined ram-extruded bar stock or group 2 polyethylene (P2) (158 patients) molded gamma-radiated argon-processed polyethylene components. The mean follow-up duration for the P1 group (89 ± 55 months) was not different from that of patients with P2 polyethylene (79 ± 63 months; p = 0.24) including 27% (18 of 66) of patients in the P1 group and 25% (40 of 158) of patients in the P2 group followed for more than 10 years. More patients in the P2 group were lost to follow-up (9.2%, 16 of 174) than in the P1 group (5.7%, 4 of 70) but this was not statistically different (chi square; p = 0.37). The hazard of revision because of polyethylene wear or breakage was calculated with a competing risk analysis using the Fine‐Gray subdistribution hazard model. Results The P1 implants had a higher hazard ratio for revision caused by polyethylene damage at 120 months than did the P2 polyethylene implants (P1 HR 0.24 [95% CI 0.13 to 0.36] versus HR 0.07 [95% CI 0.03 to 0.12]), which represents an estimated absolute risk reduction of 17% (95% CI 6.15 to 27.9). Conclusion Polyethylene damage can result in megaprosthetic revisions in patients undergoing oncologic procedures. The hazard of polyethylene failure resulting in revision surgery was lower in patients who received recent polyethylene than in patients with polyethylene produced by previous methods, enhancing the durability of distal femoral megaprosthetic reconstructions. Despite improvements in polyethylene manufacture and clinical results, revision solely because of polyethylene damage still occurs in 7% of patients by the 10-year timepoint; thus, more improvement is needed . Patients who receive these implants should be monitored for signs and symptoms of polyethylene damage. Level of Evidence Level III, therapeutic study.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
9秒前
温婉的连虎完成签到,获得积分10
15秒前
27秒前
标致的元蝶完成签到,获得积分10
29秒前
dyr完成签到,获得积分10
30秒前
dyr发布了新的文献求助10
33秒前
朝圣完成签到,获得积分10
34秒前
淡然的凡之完成签到,获得积分10
52秒前
kkjust完成签到,获得积分10
56秒前
秉朔完成签到 ,获得积分10
1分钟前
1分钟前
感动的天德完成签到,获得积分10
1分钟前
所所的应助被研友_闾丘枫采纳,获得10
1分钟前
怎样发布了新的文献求助10
1分钟前
1分钟前
1分钟前
科研通AI6.4的应助被怎样采纳,获得10
1分钟前
大模型的应助被科研通管家采纳,获得10
1分钟前
安安爱阎魔完成签到,获得积分10
1分钟前
miaomiao123完成签到 ,获得积分10
1分钟前
自由的冷玉完成签到,获得积分10
1分钟前
温暖的忆霜完成签到,获得积分10
2分钟前
ranj完成签到,获得积分10
2分钟前
充电宝的应助被mouhao采纳,获得10
2分钟前
zcc111完成签到,获得积分10
2分钟前
2分钟前
mouhao发布了新的文献求助10
2分钟前
3分钟前
south完成签到,获得积分10
3分钟前
3分钟前
英俊的铭的应助被mouhao采纳,获得10
3分钟前
漂亮的宛筠完成签到,获得积分10
3分钟前
south发布了新的文献求助10
3分钟前
拿云发布了新的文献求助10
3分钟前
靓丽的伟祺完成签到,获得积分10
3分钟前
FashionBoy的应助被拿云采纳,获得10
3分钟前
mouhao完成签到,获得积分10
3分钟前
朝朝暮夕完成签到 ,获得积分10
3分钟前
meeteryu完成签到,获得积分10
3分钟前
白夜完成签到,获得积分10
3分钟前
高分求助中
(应助此贴封号)通过应助OA文献获取积分 10000
Rosenblum, Global Change Biology 800
Computational Chemical Reaction Engineering: Modeling, Simulation, and Design with MATLAB 600
Organizational Behavior 510
Management and the Arts 510
Deformation and Fracture of the Lumbar Vertebral End Plate 500
CLSI C56QG Examples of Hemolyzed, Icteric, and Lipemic/Turbid Samples Quick Guide 400
热门求助领域 (近24小时)
化学 材料科学 医学 生物 计算机科学 工程类 纳米技术 内科学 物理 有机化学 化学工程 生物化学 复合材料 光电子学 细胞生物学 心理学 量子力学 催化作用 物理化学 电极
热门帖子
关注 科研通微信公众号,转发送积分 7802259
求助须知:如何正确求助?哪些是违规求助? 9336510
关于积分的说明 20480024
捐赠科研通 7393806
什么是DOI,文献DOI怎么找? 3326848
关于科研通互助平台的介绍 2473780
邀请新用户注册赠送积分活动 2344883