摘要
Background: Ranges of corneal tissue removal and residual stroma are the most essential safety consideration for corneal refractive procedures and directly determine the eligibility of candidates who may benefit from surgery. Small-incision lenticule extraction (SMILE), a laser procedure, has been performed for more than 10 years with well-established efficacy and predictability. However, determining the optimal safety limit for corneal tissue removal is still a challenge, perplexing surgeons. Main text: , the ratio of MLT to preoperative central corneal thickness (CCT)). Thin corneas (<500 μm) and eyes with extremely high myopia (>-9 D) were regarded as two special conditions for independent analysis. Results: to prevent forward shifts following SMILE were 140-145 μm and 27%-28%, respectively. In meta-analysis, the safety index in thin corneas and extremely high myopia were 1.07 (95% CI: 0.98-1.15) and 1.17 (95% CI: 1.12-1.21), respectively. For thin corneas, the stiffness parameter at first applanation (SP-A1) exhibited less reduction compared to normal corneas after equal tissue removal, indicating biomechanical safety with minimal stiffness alteration. Conclusions: (28%) may serve as benchmarks for establishing safety thresholds for corneal tissue removal and residual stroma in SMILE. Biomechanical assessments, like SP-A1, may be promising indicators, while the preoperative CCT has limited association with postoperative morphological and biomechanical stability.