Accuracy and Feasibility of Real-time Continuous Glucose Monitoring in Critically Ill Patients After Abdominal Surgery and Solid Organ Transplantation

医学 病危 连续血糖监测 重症监护医学 移植 糖尿病 1型糖尿病 外科 内分泌学
作者
Barbora Voglová Hagerf,Marek Protuš,Lenka Németová,Miloš Mráz,Eva Kieslichová,Eva Uchytilová,Veronika Indrova,Jan Lelito,Peter Girman,Martin Haluzı́k,Janka Franeková,Veronika Švirlochová,David C. Klonoff,Michael A. Kohn,A Jabor
出处
期刊:Diabetes Care [American Diabetes Association]
卷期号:47 (6): 956-963 被引量:27
标识
DOI:10.2337/dc23-1663
摘要

OBJECTIVE Glycemia management in critical care is posing a challenge in frequent measuring and adequate insulin dose adjustment. In recent years, continuous glucose measurement has gained accuracy and reliability in outpatient and inpatient settings. The aim of this study was to assess the feasibility and accuracy of real-time continuous glucose monitoring (CGM) in ICU patients after major abdominal surgery. RESEARCH DESIGN AND METHODS We included patients undergoing pancreatic surgery and solid organ transplantation (liver, pancreas, islets of Langerhans, kidney) requiring an ICU stay after surgery. We used a Dexcom G6 sensor, placed in the infraclavicular region, for real-time CGM. Arterial blood glucose measured by the amperometric principle (ABL 800; Radiometer, Copenhagen, Denmark) served as a reference value and for calibration. Blood glucose was also routinely monitored by a StatStrip bedside glucose meter. Sensor accuracy was assessed by mean absolute relative difference (MARD), bias, modified Bland-Altman plot, and surveillance error grid for paired samples of glucose values from CGM and acid-base analyzer (ABL). RESULTS We analyzed data from 61 patients and obtained 1,546 paired glucose values from CGM and ABL. Active sensor use was 95.1%. MARD was 9.4%, relative bias was 1.4%, and 92.8% of values fell in zone A, 6.1% fell in zone B, and 1.2% fell in zone C of the surveillance error grid. Median time in range was 78%, with minimum (<1%) time spent in hypoglycemia. StatStrip glucose meter MARD compared with ABL was 5.8%. CONCLUSIONS Our study shows clinically applicable accuracy and reliability of Dexcom G6 CGM in postoperative ICU patients and a feasible alternative sensor placement site.
最长约 10秒,即可获得该文献文件

科研通智能强力驱动
Strongly Powered by AbleSci AI
更新
PDF的下载单位、IP信息已删除 (2025-6-4)

科研通是完全免费的文献互助平台,具备全网最快的应助速度,最高的求助完成率。 对每一个文献求助,科研通都将尽心尽力,给求助人一个满意的交代。
实时播报
xelloss完成签到,获得积分10
刚刚
葛力发布了新的文献求助10
刚刚
1秒前
搜集达人应助格格巫采纳,获得10
2秒前
oyxz完成签到,获得积分10
3秒前
taotao完成签到,获得积分10
5秒前
在写了发布了新的文献求助10
5秒前
Galaxy8完成签到,获得积分10
7秒前
nini完成签到,获得积分10
10秒前
楠木木完成签到 ,获得积分10
11秒前
杨123完成签到,获得积分10
11秒前
12秒前
fanshesanniang关注了科研通微信公众号
12秒前
在写了完成签到,获得积分10
14秒前
15秒前
15秒前
16秒前
荣安安完成签到,获得积分10
17秒前
yolo完成签到,获得积分10
17秒前
YJ完成签到,获得积分0
17秒前
格格巫发布了新的文献求助10
18秒前
semigreen完成签到 ,获得积分10
18秒前
longmy发布了新的文献求助10
19秒前
21秒前
CodeCraft应助巧克力大王采纳,获得10
21秒前
21秒前
在水一方应助遇见采纳,获得10
22秒前
荣安安发布了新的文献求助10
22秒前
葛力发布了新的文献求助10
24秒前
26秒前
26秒前
菲菲完成签到,获得积分10
27秒前
老福贵儿应助lnx采纳,获得10
30秒前
30秒前
吃宝宝完成签到,获得积分10
30秒前
瘦瘦妖妖发布了新的文献求助10
31秒前
WWwww完成签到,获得积分10
32秒前
Qingcyx完成签到,获得积分10
32秒前
33秒前
35秒前
高分求助中
Pipeline and riser loss of containment 2001 - 2020 (PARLOC 2020) 1000
哈工大泛函分析教案课件、“72小时速成泛函分析:从入门到入土.PDF”等 660
Learning and Motivation in the Classroom 500
Theory of Dislocations (3rd ed.) 500
Comparing natural with chemical additive production 500
The Leucovorin Guide for Parents: Understanding Autism’s Folate 500
Phylogenetic study of the order Polydesmida (Myriapoda: Diplopoda) 500
热门求助领域 (近24小时)
化学 医学 生物 材料科学 工程类 有机化学 内科学 生物化学 物理 计算机科学 纳米技术 遗传学 基因 复合材料 化学工程 物理化学 病理 催化作用 免疫学 量子力学
热门帖子
关注 科研通微信公众号,转发送积分 5225537
求助须知:如何正确求助?哪些是违规求助? 4397211
关于积分的说明 13686001
捐赠科研通 4261743
什么是DOI,文献DOI怎么找? 2338660
邀请新用户注册赠送积分活动 1336070
关于科研通互助平台的介绍 1291974