静态混合器
静压
还原(数学)
计算流体力学
功率(物理)
工程类
静态分析
工艺工程
模拟
汽车工程
材料科学
电子工程
化学
分析化学(期刊)
航空航天工程
色谱法
物理
数学
结构工程
热力学
几何学
作者
Zhanzhou Pang,Ranjing Chen,Yue Cao
出处
期刊:Energies
[Multidisciplinary Digital Publishing Institute]
日期:2022-11-28
卷期号:15 (23): 8977-8977
被引量:12
摘要
In order to solve the poor flow performance issues of selective catalytic reduction (SCR) denitration systems, the effect of the static mixer on the flow field was studied using computational fluid dynamics (CFD) numerical simulations. Based on the analysis of the original SCR denitration system, two static mixers were selected to explore their influence on system performance. The results show that both static mixers can effectively improve the denitration performance under different conditions. The static mixer with a rotating arrangement showed a better performance in the uniformity of concentration. The pressure loss without a static mixer is 834 Pa, and the pressure loss increases by 94 Pa and 73 Pa for rotating and X-arranged static mixers, respectively. Meanwhile, a static mixer will increase energy loss. Therefore, power plants can choose the layout of their static mixers according to the actual situation to achieve the optimal performance.
科研通智能强力驱动
Strongly Powered by AbleSci AI