In this study, an applied voltage waveform of a cryogenic ultrasonic motor driven by a sawtooth vibration has been changed from a sine wave to a square wave to simplify the driving system. The ultrasonic motor using a torsional transducer has been evaluated by using the waveform. First, a square driving voltage wave which have been applied was founded, and then, optimal square wave to excite the sawtooth vibration waveform to the transducer was determined. Next, driving performance of the ultrasonic motor was evaluated. The rotation speed was 174rpm and the starting torque was 2.17mNm at 4.5K. These values are 57% and 286% larger than previous results using the sine wave driving. Furthermore, a velocity control was carried out in the low-speed range using a burst drive.