医学
预加载
血流动力学
心力衰竭
脉动流
心脏病学
血压
内科学
心输出量
循环系统
人工心脏
不利影响
心室辅助装置
冲程容积
心功能曲线
冲程(发动机)
铅(地质)
麻醉
临床试验
中心静脉压
随机对照试验
外科
心脏移植
心脏周期
心率
作者
Arjang Ruhparwar,Stephan Schueler,Ulrich Stock,Jasmin Sarah Hanke,Jan Dieter Schmitto,Henning Pauli,Jan Karsten,Christian Holdflod Møller,P H Møller-Sørensen,M Schmid,Adam Kenneth McDiarmid,Johann K Bauersachs,Stephen M. Wildhirt,Bastian Schmack
摘要
AIMS: Mechanical Circulatory Support (MCS) remains limited in advanced heart failure due to blood-contact complications and the absence of biventricular support. We report the first prospective clinical trial of a novel soft-robotic, biventricular, pulsatile technology placed externally around the heart without blood contact, designed to deliver individualized cardiac assistance (reBEAT®, AdjuCor GmbH, Munich, Germany). METHODS AND RESULTS: The system was temporarily applied in 10 end-stage heart failure patients immediately before elective LVAD implantation. Devices were custom-manufactured using preoperative CT scans to match individual cardiac anatomy. Safety, feasibility, and effects on haemodynamics were evaluated. Implantation was rapid (3±2 min), demonstrating procedural feasibility. We observed two procedure-related adverse events while no device- or procedure-related severe adverse events occurred. Absence of new ECG abnormalities, and no tissue injury confirmed safety. An iterative assessment on haemodynamics provided key insights into individualized cardio-circulatory support. While device presence reduced preload dependent haemodynamics in some patients, low average support pressures of 65-66 mmHg produced variable improvements towards baseline, predominantly on the pressure signal: mean arterial pressure (MAP; 67.5 ± 10.6 vs. 76.2 ± 11.7 mmHg, p<0.01), stroke work (SW; 347.8 ± 118.2 vs. 434.1 ± 131.0 mJ, p<0.01), and cardiac power output (CPO; 407.9 ± 108.2 vs. 503.7 ± 116.2 mW, p<0.01). Additionally, effects were observed on atrioventricular valve function and interventricular balance, which were not significant. CONCLUSION: This soft-robotic biventricular MCS platform provides short term evidence of a safe and feasible approach to pulsatile biventricular support without blood contact. Significant increases in MAP, CPO, and SW towards baseline indicate functional effects. Continuous device-driven workflow improvement is mandatory and further data are required to refine individualized optimization strategies. This technology may offer a novel biventricular assist modality. Its reduced complexity may enable broader adaption for both temporary and durable support. Avoiding blood contact and enabling balanced biventricular assistance will be central drivers of its continued clinical development.
科研通智能强力驱动
Strongly Powered by AbleSci AI