作者
Claudio Demaria,Claudio Crema,Mario Verdicchio,Valentina Brancato,Vincenzo Alfano,Luca Basso,Giuseppe Pontillo,Damiano Archetti,Silvia Fostinelli,Silvia De Francesco,Michela Pievani,Cesare Michele Baronio,Alberto Boccali,Nicola Toschi,Arturo Brunetti,Alberto Redolfi,Marco Aiello
摘要
RATIONALE AND OBJECTIVES: Automated semantic classification of radiology reports can enhance clinical workflows and research, but often relies on language- and task-specific models, limiting scalability. This study aims to evaluate and improve the 0-shot baseline performance of open-weight large language models (LLMs) in the semantic classification of free-text magnetic resonance imaging (MRI) reports. MATERIALS AND METHODS: A corpus of 1385 reports from a single neuroradiology center was used to assess four LLMs (GPT-OSS-20B, Magistral-Small-2509, Gemma-4-31B, Qwen3.5-35B-A3B) of comparable scale (∼20-35B parameters). The brain MRI reports were labeled as Pathological or Non-Pathological, with the Pathological ones further classified into five diagnostic categories (Neoformation, Vascular, Inflammation/Infection, Neurodegenerative, Other). The LLMs were evaluated using zero- and few-shot prompting with majority-vote aggregation. Quantized Low-Rank Adaptation (QLoRA) fine-tuning was then applied to the best-performing model across multiple configurations. Performance was assessed using Macro F1, Micro F1, Precision, Recall, and Exact Match Accuracy. RESULTS: The binary classification task achieved a Macro F1 score of 0.84 on the best-performing Qwen3.5-35B-A3B model, while multilabel classification reached 0.81. Majority voting (MV) outperformed individual-set predictions. QLoRA fine-tuning yielded a Macro F1 score of 0.83 on the multilabel task; the improvement over the 0-shot baseline was statistically supported for Macro F1, Micro F1, Macro Precision, and Exact Match, whose bootstrap 95% confidence intervals excluded zero, but not for Macro Recall. Fine-tuning and few-shot prompting strategies are complementary, with neither consistently outperforming the other. Error analysis showed that the models struggled with borderline annotation cases and often missed secondary labels. CONCLUSION: Open-weight LLMs demonstrate strong capability for neuroradiology report classification without extensive task-specific training. Fine-tuning further improves performance, supporting integration into scalable semantic radiology data pipelines. However, the present evidence comes from a single Italian center without external validation, and the fine-tuning gain was estimated on a small held-out test set, for which the Macro F1 improvement, though statistically significant, has a confidence interval with a lower bound close to zero. In this light, the approach is best positioned as an internal indexing and semantic-retrieval tool, supporting faster report retrieval, structured cohort identification, internal audit, and scalable phenotyping for neuroradiology research and data warehousing, as well as efficient active-learning strategies, with broader generalizability requiring additional external multicentre validation before clinical deployment.