医学
患者满意度
外科
回顾性队列研究
不利影响
多中心研究
牙科
可视模拟标度
生理盐水
小瓶
事后
迟钝的
析因分析
患者依从性
面部修复
聚己内酯
3d打印
随机对照试验
作者
So Eun Kim,Seung Min Oh,Min Seong Kim,Wook Oh,Jino Kim
出处
期刊:The Aesthetics
[The Korean Association for Laser, Dermatology and Trichology]
日期:2026-10-30
卷期号:6 (1): 11-18
标识
DOI:10.46738/aesthetics.26.0004
摘要
Background and Objectives Polycaprolactone (PCL) is a biodegradable, collagen-biostimulatory polymer used in facial rejuvenation. GOURI ® is a liquid-form aqueous PCL formulation that differs from conventional microsphere suspensions, which provide both immediate volume and longer-term collagen stimulation. Multicenter routine-practice data on cannula-delivered facial treatment with this formulation are limited. This study evaluated short-term outcomes after a standardized cannula-based liquid-form PCL protocol. Materials and Methods Charts of adults treated at five Korean aesthetic clinics between October 2025 and January 2026 were retrospectively reviewed. Per protocol, one vial of GOURI ® was diluted with saline (1:3) and delivered via 25–30 G blunt cannulas to the bilateral temple nd zygomatic entry points using the fanning technique (0.5–1.5 cc per point, 4.0 cc total). Investigator modified Global Aesthetic Improvement Scale scores (nine items), patient satisfaction scores (11 items), and adverse events at 1 month were extracted from patient records. Because of the scale’s ceiling effect, a post hoc top-box analysis (“markedly improved” ratings) was added. Results Nine procedures at four clinics were analyzed. All patients were females (mean age, 44.2 ± 10.8 years). Mean investigator and patient questionnaire scores were 4.15 ± 0.30 and 4.07 ± 0.26, respectively. Overall satisfaction and willingness to recommend both scored 4.44 ± 0.53, and 100% of patients rated them ≥ 4. Elasticity and texture were rated highest (both 4.67 ± 0.50; top-box rate, 66.7%). Redness and hydration scored comparatively low. No adverse events (nodules, inflammation, edema, pigment changes, or hypersensitivity) were recorded. Conclusion Cannula-delivered liquid-form PCL was associated with favorable 1-month investigator- and patient-reported outcomes, particularly for skin elasticity and texture, with high patient satisfaction. Given the small, uncontrolled retrospective design, non-validated in-house instruments, and short follow-up, these findings are hypothesis-generating. They require confirmation in larger prospective controlled studies with objective assessments.
科研通智能强力驱动
Strongly Powered by AbleSci AI