固相微萃取
邻苯二甲酸
纤维
石墨烯
涂层
化学
重复性
检出限
材料科学
气相色谱法
色谱法
氧化物
火焰离子化检测器
气相色谱-质谱法
有机化学
质谱法
纳米技术
作者
Shuaihua Zhang,Qian Yang,Zhi Li,Wenjin Wang,Xiaohuan Zang,Chun Wang,Zhi Wang
出处
期刊:Food Chemistry
[Elsevier BV]
日期:2018-04-30
卷期号:263: 258-264
被引量:79
标识
DOI:10.1016/j.foodchem.2018.04.132
摘要
Abstract A hybrid composite featuring an iron-based metal-organic framework Material of Institute Lavoisier-88(Fe) and graphene oxide (MIL-88(Fe)/GO) was synthesized and used as the solid-phase microextraction (SPME) coating. The SPME fiber was prepared by covalent bonding of the MIL-88(Fe)/GO composite onto the stainless steel substrate. The fiber had a good durability and allowed >100 replicate extractions. The developed method, which combined the MIL-88(Fe)/GO coated fiber based SPME with gas chromatography-flame ionization detection (GC-FID), achieved low limits of detection (0.5–2.0 ng g−1, S/N = 3) and good linearity (r2 > 0.994) for the phthalic acid esters (PAEs) from various vegetable oil samples. The repeatability and fiber-to-fiber reproducibility were in the range of 4.0–9.1% and 5.7–11.4%, respectively. The method was successfully applied to the analysis of PAEs from vegetable oil samples with good recoveries (83.1–104.1%) and satisfactory precisions (RSDs