生物相容性
明胶
生物相容性材料
材料科学
纳米技术
生物医学工程
化学
复合材料
医学
冶金
生物化学
作者
He Tao,Ximin Yuan,Debin Shan,Bin Qiang Guo,Jie Xu
出处
期刊:Langmuir
[American Chemical Society]
日期:2025-01-10
卷期号:41 (3): 1675-1683
被引量:3
标识
DOI:10.1021/acs.langmuir.4c03834
摘要
Flexible electronic patches have been widely studied in various fields. However, they still face serious challenges in cardio-brain signaling monitoring to achieve accurate adhesion and detection with compatibility in mildly humid environments. To tackle these challenges, we engineered a gelatin hydrogel film cross-linked with a biocompatible matrix factor and combined it with a blend of liquid metal and PVP to create the flexible electronic patch. The flexible patch has good biocompatibility and fatigue resistance due to the incorporation of liquid metal and natural gelatin, with the conductivity of liquid metal and minimal toxicity of the gelatin film. It is possible to securely insert it into the body for a duration of 3 weeks while maintaining monitoring functionality and withstanding 10 000 cycles of flexural fatigue. This research provides an innovative approach to the future advancement of flexible electronic patches.
科研通智能强力驱动
Strongly Powered by AbleSci AI