热交换器
流出物
材料科学
管壳式换热器
核工程
废物管理
机械工程
工程类
作者
Duane Serate,J. Lindmark,Simon Yuen,Aaron McDonald,Trevor Kreeft,Jesus Tirado,Yashar Behnamian,James R. Campbell
出处
期刊:Conference proceedings
[Institute of Electrical and Electronics Engineers]
日期:2025-04-06
卷期号:: 1-11
摘要
Abstract Non-ferromagnetic heat exchanger tubes are typically inspected using conventional eddy current bobbin probes to gather data on the integrity of the tubes. This technique provides operators with useful information on pitting and longitudinal cracks, but technical limitations of the conventional eddy current process leaves operators with limited ability to detect circumferential flaws and cracks. In this paper, extensive circumferential chloride stress corrosion cracks, originating from the tube outside diameter, were found by Eddy Current Array (ECA) in the front portion of SA 213 TP 321 SS tubes of a hydrocracker unit feed-effluent heat exchanger. The crevices between the tubes and the tube sheet trap chlorides in both normal operation, and in downtime. Deployment of ECA technology eliminates the limitations of conventional EC bobbin coil probes, effectively identifying circumferential cracking as well as pitting and axial cracking.
科研通智能强力驱动
Strongly Powered by AbleSci AI