医学
烧蚀
低温消融
肺静脉
心脏病学
内科学
心房颤动
射频消融术
不利影响
导管消融
心房扑动
随机对照试验
膈神经
透视
狭窄
外科
麻醉
放射科
房性心动过速
镇静
热烧蚀
烧蚀区
耐火材料(行星科学)
作者
Shaojie Chen,Ramin Ebrahimi,Mu Qin,Jingquan Zhong,Kai Zhang,Huimin Chu,Christian G. Meyer,Andreas Rillig,Kars G.E.J. Neven,Christian-Hendrik H. Heeger,Maura M. Zylla,Laura Perrotta,Martin Huth Ruwald,Piotr Futyma,Bart A. Mulder,Rui Zeng,Hongde Hu,Márcio Galindo Kiuchi,Hailei Liu,Minglong Chen
标识
DOI:10.1161/circep.126.015020
摘要
BACKGROUND: Pulsed field ablation (PFA) is an increasingly adopted, minimally thermal modality for the ablation of atrial fibrillation, but its comparative performance versus contemporary thermal ablation strategies remains incompletely defined. We conducted an aggregate-data meta-analysis of contemporary randomized trials to compare procedural performance, safety, and clinical outcomes of PFA versus cryoballoon ablation and radiofrequency ablation in paroxysmal atrial fibrillation. METHODS: A systematic search identified 6 contemporary randomized controlled trials enrolling 2015 patients with paroxysmal atrial fibrillation. Study-level random-effects meta-analyses were performed to compare procedural performance, peri-procedural safety, and atrial arrhythmia recurrence, with predefined subgroup analyses according to thermal ablation modality. RESULTS: PFA was associated with significantly shorter procedure time, left atrial dwell time, and total ablation time than thermal ablation (all P <0.001), whereas fluoroscopy time and anesthetic strategy were comparable between groups. PFA was associated with a significantly lower risk of peri-procedural serious adverse events than thermal ablation (risk ratio, 0.58 [95% CI, 0.35–0.96]; P =0.036). Persistent phrenic nerve palsy and pulmonary vein stenosis occurred exclusively after thermal ablation. Overall, PFA was associated with a lower risk of atrial arrhythmia recurrence than pooled thermal ablation (risk ratio, 0.86 [95% CI, 0.75–0.99]; P =0.03). Subgroup analyses demonstrated a significant reduction in recurrence compared with cryoballoon ablation (risk ratio, 0.80 [95% CI, 0.65–0.97]; P =0.03), whereas outcomes were comparable between PFA and contemporary radiofrequency (risk ratio, 0.93 [95% CI, 0.77–1.13]; P =0.48). CONCLUSIONS: PFA provides greater procedural efficiency, improved peri-procedural safety, and a lower risk of atrial arrhythmia recurrence than pooled thermal ablation in patients with paroxysmal atrial fibrillation. The efficacy advantage was primarily driven by comparisons with cryoballoon ablation, whereas outcomes were comparable between PFA and contemporary RFA.