摘要
Background This study examined whether changing the head position from neutral to side can affect expiratory tidal volume (TV) and cuff pressure when the appropriate sizes of a Proseal⢠Laryngeal Mask Airway (PLMA)-depending on the body weight -are used in pediatric patients during pressure controlled ventilation (PCV). Methods Seventy-seven children (5-30 kg) were divided into three groups according to their body weight, PLMA#1.5 (group I, n = 24), #2 (group II, n = 26), and #2.5 (group III, n = 27). After anesthesia induction, a PLMA was placed with a cuff-pressure of 60 cmH2O. The TV and existence of leakage at the peak inspiratory pressure (PIP) of 20 cmH2O, and the appropriate PIP for TV 10 ml/kg were examined. Upon head rotation to the left side, the TV, PIP, cuff pressure changes, and the appropriate PIP to achieve a TV 10 ml/kg were evaluated. Results Head rotation of 45 degrees to the left side during PCV caused a significant increase in cuff pressure and a decrease in TV, and there was no definite leakage. Changes in PIP and TV were similar in the three groups. The cuff pressure increased but there was no significant difference between the three groups. Conclusions Although cuff pressure and TV of the PLMA were changed significantly after turning the head from the neutral position to the side, a re-adjustment of the cuff pressure and PIP to maintain a TV of 10 ml/kg can make the placed PLMA useful and successful in pediatric patients under general anesthesia. Keywords: Head rotation; Pediatrics; PLMA.