内压
材料科学
巴(单位)
断裂(地质)
J积分
结构工程
有限元法
强度因子
断裂力学
机械
复合材料
地质学
工程类
物理
海洋学
作者
Laouni Gaidi,Abdelhak Ouldyerou,L. Aminallah,Ali Merdji,Sandipan Roy,Mohammed Sid Ahmed Houari
标识
DOI:10.1177/09544062231221874
摘要
Cracks in pipes used for water transfer have been identified as a significant contributor to water loss and potential failures. To assess fracture behavior, the J-integral was computed for 3D finite element HDPE pipes (DN 355) with axial internal and external cracks (with a/ c and a/ t ratios of 0.5) subjected to a range of internal pressure (16–30 bar) and crack face load condition. Four ratios of a/ c ranging from 0.3 to 0.9 (with an increment of 0.2) were examined with the internal crack. Results indicate that under face crack loading, the external axial crack exhibits a higher J-integral intensity than the internal axial crack. J-integral values greater than 8.4 kJ/m 2 were found to lead to pipe failure, with higher internal pressures (25–30 bar for external crack, and 30 bar for internal pressure). Moreover, the a/ c ratio plays a significant role in influencing the distribution of J-integral along internal crack arc length. For pipes of DN 355 size with axial cracks, internal pressure exceeding 20 bar is not recommended. These findings underscore the importance of considering J-integral values in pipe design to prevent failure.
科研通智能强力驱动