腐蚀
骨料(复合)
超声波传感器
层次分析法
硫酸盐
材料科学
超声波检测
结构工程
复合材料
声学
工程类
冶金
物理
运筹学
作者
Dunwen Liu,Chun Gong,Yu Tang,Yinghua Jian,Kunpeng Cao,Haofei Chen
出处
期刊:Sensors
[Multidisciplinary Digital Publishing Institute]
日期:2022-04-15
卷期号:22 (8): 3037-3037
被引量:22
摘要
Coarse aggregate in concrete is basically free from sulfate corrosion. If the influence of the coarse aggregate in the concrete is not eliminated, the change amount of the concrete ultrasonic pulse velocity value is directly used to evaluate the damage degree of sulfate corrosion in the concrete, and the results are often inaccurate. This paper presents an evaluation method of corrosion damage for the sulfate-attacked concrete by CT, ultrasonic velocity testing and AHP methods. CT was used to extract the coarse aggregate information in the specimen, and the proportion of coarse aggregate on the ultrasonic test line was calculated based on CT image analysis. Then, the correction value of ultrasonic pulse velocity (UPV) of the concrete structure was calculated, and the sulfate corrosion degree of concrete structure was evaluated using the analytic hierarchy process (AHP). The results show that the evaluation method proposed in this paper could more accurately evaluate the corrosion damage in the sulfate-attacked concrete structures, and the evaluation results were more in line with reality.