随机对照试验
自动化
读写能力
医学教育
健康素养
医学
心理学
计算机科学
短信
人工智能
自然语言处理
梅德林
护理部
数字素养
临床试验
医学物理学
自动推理
决策辅助工具
家庭医学
应用心理学
作者
Ihsan Ayyub Qazi,Ayesha Ali,Asad Ullah Khawaja,Muhammad Junaid Akhtar,Ali Zafar Sheikh,Muhammad Hamad Alizai
出处
期刊:
日期:2026-04-23
卷期号:3 (5): AIoa2501001-AIoa2501001
被引量:27
摘要
BACKGROUND: Large language models (LLMs) have the potential to improve clinical reasoning, but can also hallucinate, generating plausible but false information that risks patient harm. This risk is amplified by automation bias, the tendency to over-rely on automated outputs. It remains unclear whether physicians formally trained to critically evaluate artificial intelligence (AI) outputs remain susceptible to this bias when LLM consultation is discretionary. METHODS: We conducted a single-blind, randomized clinical trial from June 20 to August 15, 2025, involving 44 physicians in Pakistan who completed a 20-hour AI literacy training program. Post training, participants were randomly assigned 1:1 to diagnose six clinical vignettes. The control group received error-free diagnostic suggestions from Chat Generative Pretrained Transformer (ChatGPT) 4o, while the treatment group received suggestions containing deliberately introduced errors for three of the six cases, which were randomly ordered to minimize anchoring bias. Physicians could voluntarily consult ChatGPT-4o's recommendations alongside standard diagnostic resources, while retaining full autonomy to accept, modify, or reject its suggestions. The primary outcome was composite diagnostic reasoning accuracy (correct differentials, supporting or opposing evidence, top-choice diagnosis, and next steps) adjudicated by three blinded physicians; the secondary outcome was top-choice diagnosis accuracy. RESULTS: Forty-four physicians (22 per group) completed 264 diagnostic cases. The physicians exposed to erroneous LLM suggestions (treatment group) had a mean diagnostic accuracy of 73.3%, representing an adjusted 14.0-percentage-point reduction compared with the control group's 84.9% (95% confidence interval [CI], -18.9 to -9.1; P<0.0001). The top-choice accuracy was 76.1% in the treatment group versus 90.5% in the control group, resulting in an adjusted 18.3-percentage-point difference (95% CI, -26.6 to -10.0). CONCLUSIONS: Physicians demonstrate substantial automation bias when exposed to erroneous LLM recommendations, even with voluntary consultation and prior AI literacy training. These findings highlight safety risks that require robust validation frameworks and regulatory safeguards before widespread clinical AI deployment. (Funded by the Learning Institute at Lahore University of Management Sciences.).
科研通智能强力驱动
Strongly Powered by AbleSci AI