Objective To establish a direct injection gas chromatography method for the determination of methane,propane, butane or isobutane in the air of workplace.Methods Methane,propane,butane or isobutane in the air of workplace were collected by a syringe or a air bag with direct injection,and then analyzed by GC.Results The method showed a good linearity with the correlation coefficient(r0.999) and the relative standard deviation 1.2%~1.6%(n = 6 ).The limit of quantification of the method was 0.50 mg/m~3.When air bag was used for sampling,methane and propane can be stored at room temperature for at least 8 days,and isobutane or butane for at least 5 or 2 days.Contrarily,when sampling with a syringe,the samples should be measured on the same day as soon as possible.Conclusion The established new method could be used for determination of methane,propane,butane or isobutane in the air of workplace.