Experiments were conducted to investigate the cavitation in the round nozzles and its influence on atomization. The liquid flow in the nozzle will induce cavitation under certain condition. It has an important influence on spray. The high-speed camera was used to observe the cavitation and spray angle. The diameters of nozzles used in the experiments were 0. 5mm,1. 0mm,1. 5mm,2. 0mm,respectively. Especially for the nozzle with 1. 5mm diameter,the length to diameter ratio was designed to vary from 2 to 9, and the tested liquid was purified water. Present results indicate that the formation of cavitation in nozzles is dynamical and the cavitation length is pulsating with high frequency and low amplitude. With the increase of the diameter of the nozzle,the injection pressure for the supercavitation condition is increased and the spray angle is also increased. The supercavitation number is decreased with the increase of the length to diameter of the nozzle but the spray angle within the range of 10° and 20° does not present a significant change. The cavitation which enhances the atomization is easier to happen in nozzle with sharp inlet than with conical inlet. The breakup mode comes to atomization for all nozzles in the supercavitation condition,except for 0. 5mm.