心脏瓣膜                        
                
                                
                        
                            阀体孔板                        
                
                                
                        
                            气球                        
                
                                
                        
                            仰卧位                        
                
                                
                        
                            心脏病学                        
                
                                
                        
                            解剖                        
                
                                
                        
                            外科                        
                
                                
                        
                            医学                        
                
                        
                    
            作者
            
                Najla Sadat,Michael Scharfschwerdt,Stefan Reichert,Buntaro Fujita,Stephan Ensminger            
         
                    
        
    
            
            标识
            
                                    DOI:10.1055/s-0044-1787701
                                    
                                
                                 
         
        
                
            摘要
            
            Abstract Objectives Very precise positioning of the transcatheter heart valve (THV) inside the degenerated SAV is a crucial factor for valve-in-valve (ViV) procedure to achieve optimal hemodynamic results. Therefore, our study aimed to investigate the impact of implantation depth on functional results after ViV procedures in a standardized in vitro setting. Methods THV (SAPIEN 3 Ultra 23-mm size) and three SAV models (Magna Ease, Trifecta, and Hancock II—all 21-mm size) were tested at different circulatory conditions in five different positions of the THV (2–6 mm) inside the SAV. Mean pressure gradient (MPG), effective orifice area (EOA), geometric orifice area (GOAmax), and pinwheeling index (PWImean) were analyzed. Results EOA and MPG of the THV did not differ significantly regarding the position inside the Magna Ease and the Hancock II (p > 0.05). However, EOA differed significantly, depending on the position of the THV inside Trifecta (2 vs. 5 mm; p = 0.021 and 2 vs. 6 mm; p < 0.001). The THV presented the highest EOA (2.047 cm2) and the lowest MPG (5.387 mm Hg) inside the Magna Ease, whereas the lowest EOA (1.335 cm2) and the highest MPG (11.876 mm Hg) were shown inside the Hancock II. Additionally, the highest GOAmax and the lowest PWImean of the THV were noticed inside the Magna Ease. The THV showed lower GOAmax and higher PWImean inside the Trifecta when placed in a deeper position. Conclusion Deep implantation of the SAPIEN 3 Ultra inside the Trifecta correlates with impaired functional results. In contrast, the implantation position of the SAPIEN 3 Ultra inside the Magna Ease and the Hancock II did not have a significant effect on functional results.
         
            
 
                 
                
                    
                    科研通智能强力驱动
Strongly Powered by AbleSci AI