医学
侧支循环
内科学
心脏病学
静脉血
接收机工作特性
冲程(发动机)
逻辑回归
放射科
外科
机械工程
工程类
作者
Jingjie Wang,Jing Li,Jiayang Liu,Jiajing Wu,Sirun Gu,Yunzhuo Yao,Tianyou Luo,Cheng Huang,Fusen Huang,Yongmei Li
标识
DOI:10.1016/j.acra.2022.12.004
摘要
To investigate the change of cortical venous flow in acute ischemic stroke patients with large vessel occlusion (LVO-AIS) and its clinical value.Baseline whole-brain 4D-CTA/CTP and clinical data of LVO-AIS and a control group were collected from June 2020 to October 2021. Venous inflow time (VIT), venous peak time (VPT), and venous outflow time (VOT) were analyzed on both sides of patients and normal controls. The VIT/VPT/VOT were statistically described and compared between the patient group and normal controls, then, in patients with different collateral circulation and prognoses. Next, the correlation between cortical venous drainage time and collateral circulation grading was analyzed. Finally, logistic regression analysis was used to explore the relationship between the three venous times and prognosis, and receiver operating characteristic (ROC) curves were plotted to assess the value of delayed cortical venous imaging in predicting prognosis.149 LVO-AIS and 73 normal controls were collected. VIT, VPT, and VOT were significantly delayed on the affected side in the patient group compared with the healthy side (p<0.05) and the controls (p<0.05); VIT and VPT were also significantly delayed on the healthy side of patients compared with the controls (p<0.05). Delayed VIT and VPT on the affected side in the patient group were more significant in patients with poor collateral circulation (p<0.05), and VIT and VPT on the affected side in the patient group were negatively correlated with arterial collateral scores. VIT and VPT were significantly delayed in both sides of patients in the poor prognosis group compared with the good prognosis group (p<0.05). logistic regression showed that patients' affected VPT, arterial collateral scores, and NIHSS were independent predictors of poor prognosis, with an accuracy of 79.6% in predicting poor prognosis. The affected VPT and NIHSS were independent predictors of poor prognosis for patients presenting within 24 hours, with an accuracy of 79.6% in predicting poor prognosis.Cortical venous flow was significantly slowed in both sides of LVO-AIS patients. delayed ipsilateral VPT in LVO-AIS patients can be used as an imaging indicator to determine poor collateral circulation and predict poor prognosis.
科研通智能强力驱动
Strongly Powered by AbleSci AI