The receding contact angles of water drops on PMMA and PET surfaces were determined by using video microscopy to follow the time-dependent evaporation of sessile drops. Depending on the initial drop size, receding angles of θ r = 54−64° for PMMA and θ r = 64−66° for PET were found with an average hysteresis of 23.5 ± 1.5 and 19.5 ± 1.5°, respectively. Advancing and receding angles, θ a and θ r, were also determined by the needle-syringe and the inclined plane methods for comparison. The discrepancies from the mean of the maximum and minimum contact angle results of both the needle-syringe and the inclined plane methods were larger than expected for all the polymer surfaces. A general trend was seen with samples giving a larger hysteresis also producing a larger discrepancy for all the samples. The major cause of this discrepancy is the variation of the rate of liquid introduction and withdrawal with the syringe in the needle-syringe method and the drop size effect in the inclined plane method. In this respect the drop evaporation method allows a rate of liquid withdrawal which minimizes (or standardizes) the linear rate of retreat effect on receding contact angle measurement. The literature values are also given for comparison. A discrepancy of 11−15% from the mean for θ a and 27−32% for θ r is reported in the literature for these polymers. This is approximately five times more than the previously claimed 2−3% deviation from the mean for θ a on the same clean homopolymer samples.