化学
色谱法
衍生化
甲醛
检出限
分析物
高效液相色谱法
稀释剂
乙腈
分析化学(期刊)
有机化学
作者
Ashish Soman,Yu-xin Qiu,Q. Chan Li
标识
DOI:10.1093/chromsci/46.6.461
摘要
A reversed-phase high-performance liquid chromatographic method (HPLC) with diode-array detection is developed and validated for the quantitative determination of formaldehyde in a drug substance. Formaldehyde (HCHO) is reacted with 2,4- dinitrophenylhydrazine (DNPH) to form a Schiff base (HCHODNPH derivatization product), which has an absorbing maximum (λmax) at 360 nm. The HPLC method employs a C8, 3-µm particle size analytical column (150 mm × 4.6 mm), 15-µL injection volume, column temperature controlled at 30°C, detection at 360 nm, and a water-acetonitrile (55:45, v/v) mobile phase at a flow rate of 1 mL/min. These conditions resolve the HCHO-DNPH product from unreacted DNPH, the drug substance and related impurities, as well as diluent peaks within 20 min. The retention time of the HCHO-DNPH product is approximately 6.4 min. The method is linear, accurate in the specified range (0.33–333 ppm), and robust based on analyte (HCHO-DNPH derivatization product) stability in standard and sample. Detection limit is 0.03 ng (0.1 ppm).
科研通智能强力驱动
Strongly Powered by AbleSci AI