控制理论(社会学)
转换器
电感器
跟踪误差
升压变换器
瞬态(计算机编程)
过零点
传递函数
电压
跟踪(教育)
循环(图论)
瞬态响应
计算机科学
工程类
电子工程
控制(管理)
数学
电气工程
人工智能
心理学
操作系统
组合数学
教育学
作者
Mauro Leoncini,Salvatore Levantino,Massimo Ghioni
标识
DOI:10.1007/s43236-020-00180-x
摘要
Abstract The right-half plane (RHP) zero in the control to output voltage transfer function of a boost converter operating in the continuous conduction mode limits the loop bandwidth. By injecting a scaled version of the inductor current into the loop, it is possible to shift the zero from the right-half plane to the left-half plane, which leads to increased stability of the control loop. This solution generates a static voltage error at the output of the converter (tracking error), which may be unacceptable in practical applications. A few strategies to mitigate or correct this tracking error have been suggested. However, they have never been fully assessed. This paper thoroughly investigates the impact of the RHP zero mitigation technique on the dynamic performance of a boost converter, and identifies the complex trade-off between the system stability, transient response, and tracking error correction capability. Based on these findings, design guidelines are provided to help maximize system performance. A representative case study is considered to highlight the performance benefits and simulation results are presented to validate the analysis.