固相微萃取
色谱法
质谱法
气相色谱-质谱法
气相色谱法
化学
环境化学
作者
Mereke Alimzhanova,Madina Mamedova,Kazhybek Ashimuly,Alham Alipuly,Yerlan Adilbekov
标识
DOI:10.1016/j.fochx.2022.100345
摘要
A simple and rapid method based on miniaturized solid-phase microextraction (mini-SPME) followed by gas chromatography–mass spectrometry was developed to identify eight endocrine disruptors (atrazine, diethylstilbestrol, hexestrol, estrone, estradiol, ethinylestradiol, norgestrel, and megestrel) in drinking water samples. Extraction parameters was optimized and further analyses was performed using them. The optimum temperature for the determination of endocrine disruptors in water was 80 °C; the optimum extraction and preincubation times were 60 and 20 min, respectively. The studied linear range of endocrine disruptors was 10.0–1000 μg mL−1. The limit of detection ranged from 0.020 to 0.087 μg mL−1. The correlation coefficient (r2) was 0.96–0.99. This research introduces a novel method for detecting analytes at extremely low concentrations, as well as the possibility of combining several detection technologies to give high-accuracy qualitative and quantitative determination of endocrine disruptors in aqueous samples.
科研通智能强力驱动
Strongly Powered by AbleSci AI