医学
前列腺癌
磁共振成像
前列腺
核医学
正电子发射断层摄影术
恶性肿瘤
活检
癌症
放射科
PET-CT
病理
内科学
作者
Matthias Eiber,Gregor Weirich,Konstantin Holzapfel,Michael Souvatzoglou,Bernhard Haller,Isabel Rauscher,Ambros J. Beer,Hans‐Jürgen Wester,Juergen E. Gschwend,Markus Schwaiger,Tobias Maurer
标识
DOI:10.1016/j.eururo.2015.12.053
摘要
Ligands of the prostate-specific membrane antigen (PSMA) show promising results in positron emission tomography (PET) imaging of prostate cancer (PCa). To compare the diagnostic performance of simultaneous gallium 68 (68Ga)-PSMA HBED-CC PET/magnetic resonance imaging (MRI) for localization of primary PCa with multiparametric magnetic resonance imaging (mpMRI) and PET alone. We performed 68Ga-PSMA HBED-CC PET/MRI in 66 men with biopsy-proven PCa. PET, mpMRI, and combined 68Ga-PSMA HBED-CC PET/MRI were independently evaluated using Prostate Imaging Reporting and Data System criteria or a 5-point Likert scale. The prostate was divided into sextants for histopathology and coregistered with imaging. Diagnostic performance for localization of malignancy was calculated based on receiver operating characteristics analysis for each modality. Regional quantitative PET tracer uptake was recorded; uptake ratio was defined as the ratio of malignant to nonmalignant prostate tissue. A total of 53 of 66 patients were eligible for analysis. mpMRI, PET, and PET/MRI detected cancer in 66% (35 of 53), 92% (49 of 53), and 98% (52 of 53) of the patients, respectively. Overall, 202 of 318 sextants (63.5%) contained cancer at pathologic examination. Simultaneous PET/MRI statistically outperformed mpMRI (area under the curve [AUC]: 0.88 vs 0.73; p < 0.001) and PET imaging (AUC: 0.88 vs 0.83; p = 0.002) for localization of PCa. Compared with mpMRI, PET imaging was more accurate (AUC: 0.83 vs 0.73; p = 0.003). PET provided a high uptake ratio between malignant versus nonmalignant tissue (5.02 [range: 0.89–29.8]), but no significant correlation was observed between quantitative PET parameters and Gleason score or prostate-specific antigen value. Simultaneous 68Ga-PSMA HBED-CC PET/MRI improves diagnostic accuracy for PCa localization both compared with mpMRI and with PET imaging alone. Further prospective studies are warranted to evaluate its potential (eg, for biopsy guidance). We examined gallium 68 (68Ga)-prostate-specific membrane antigen (PSMA) HBED-CC positron emission tomography/magnetic resonance imaging (PET/MRI) for primary prostate cancer (PCa) and compared it with multiparametric MRI and PET alone. Our results indicate a higher diagnostic accuracy for 68Ga-PSMA HBED-CC PET/MRI that may help localize PCa.
科研通智能强力驱动
Strongly Powered by AbleSci AI